Editor's Note: Minutes received 7/28

CURRENT_MEETING_REPORT_

Reported by Tracy Cox/Bellcore

Minutes of the DS1/DS3 MIB Working Group (TRUNKMIB)

The decision of the Working Group, per Bill Versteeg's suggestion, was
to completely obsolete RFC 1232 and RFC 1233, and remove all of the
deprecated objects from this document.  All tables have been given new
names and new OIDs.  The beginning delimiter for all objects is dsx* (*
= 1 or 3).  In addition, we added LESs to the near end tables, changed
all Counters remaining (current table) to Gauges, and modified the
dsx1LineCoding, dsx1LineStatus, dsx*SendCode Object descriptions, and
added a Signaling Mode object (DS1 MIB only).  We have an action item to
resolve on whether to keep or remove the BPVs count.

James Watt took an action item to supply appropriate text for the
failure states description.  A description of Line Errored Seconds
(which T1M1 has available only from the far end, but we decided to
include for the near end for symmetry's sake) was added.

The DS1 and DS3 MIBs are available for anonymous FTP at fennel.acc.com.

New Internet Drafts reflecting these changes will be sent to the
trunk-mib mailing list and posted in the Internet-Drafts Directories;
when consensus is achieved on the mailing list, they will be forwarded
to the IESG for their review and approval as new RFCs obsoleting RFC1232
and RFC1233.

Attendees

Fred Baker               fbaker@acc.com
Alan Bryenton            bryenton@bnr.ca
Steve Buchko             stevebu@newbridge.com
Greg Celmainis           gregc@newbridge.com
Tracy Cox                tacox@sabre.bellcore.com
James Davin              jrd@ptt.lcs.mit.edu
Tom Easterday            tom@cic.net
John Labbe               labbe@merit.edu
Chris Sullivan           mm@gandalf.ca
Kaj Tesink               kaj@cc.bellcore.com
James Watt               jamesw@newbridge.com



                                   1